PIP RESP003V

Click here to purchase
This Practice provides requirements for design and manufacture of vertical centrifugal pumps of 150 kW (200 HP) or greater used for water services.

Comment: Water services include condensate, cooling water, demineralized water, utility water, produced water, treated water, etc.

Comment: General water services include condensate, cooling water, demineralized water, utility water, produced water, treated water, etc.

This Practice describes manufacturing and performance requirements for vertical centrifugal pumps and their accessories.

This Practice covers pumps with service conditions within the following limits:
a. Maximum discharge pressure 35 Barg (500 psig)
b. Minimum pumping temperature 0°C (32°F)
c. Maximum pumping temperature 150°C (300°F)
d. Maximum rotational speed 3,600 rpm

Comment: For services outside these conditions and those that fall within the capabilities of ANSI/ASME pumps, it is recommended that PIP RESP73V be used for purchase of pumps.

Comment: For services within the capabilities of ANSI/ASME pumps, use PIP RESP73V.

Pumps covered by this Practice are classified as diffuser-and-volute, separate discharge cantilevered, and vertical can.

Vertical in-line and submersible pumps have special design characteristics and are not included in the scope of this Practice.

Fire water pumps are covered by NFPA 20 and are not covered by this Practice.

Product Details

Published:
01/01/2020
Number of Pages:
32
File Size:
1 file , 700 KB
PIP RESP003V

Click here to purchase
This Practice provides the supplier with requirements for design and manufacture of vertical centrifugal pumps that are used for water services. Water services include condensate, cooling water, demineralized water, utility water, produced water, treated water, fire water, etc.

This Practice covers manufacturing and performance requirements for vertical centrifugal pumps and their accessories. Pumps covered by this Practice are broadly classified as diffuser-and-volute, separate discharge cantilevered, and vertical can. Vertical in-line and submersible pumps have special design characteristics and are not included in the scope of this Practice.

Service Conditions
Pumps with service conditions within the limits listed below are covered in this Practice:

Maximum Discharge Pressure 3,500 kPa (500 psig)
Minimum Pumping Temperature 0° C (32° F)
Maximum Pumping Temperature 150° C (300° F)
Maximum Rotational Speed 3,600 RPM

Product Details

Published:
02/01/2004
File Size:
1 file , 240 KB